D2RF Series
Optex FA
Alta velocidad: hasta 60 micro segundos de respuesta.
6 métodos de aprendizaje.
2 display de 4 segmentos.
IP66 e IP50.
Prevención de crosstalk.
Ajuste de la potencia de emisión del LED.
Automatic tunning.
replica watches
Model | Standard | Mark sensor | Analogue | ||
Stand-alone Type | |||||
IP50 type | Cable type NPN / PNP | D2RF-TN / TP | D2GF-TN / TP | D2RF-TAN / TAP | |
M8 QD 4pin, NPN / PNP | D2RF-TCN4 / TCP4 | D2GF-TCN4 / TCP4 | NA | ||
IP66 type | Cable type NPN / PNP | D2RF-2TN / 2TP | D2GF-2TN / 2TP | D2RF-2TAN / 2TAP | |
M8 QD 4pin, NPN / PNP | D2RF-2TCN4 / 2TCP4 | D2GF-2TCN4 / 2TCP4 | NA | ||
M8 QD 3pin, NPN / PNP | D2RF-2TCN3 / 2TCP3 | D2GF-2TCN3 / 2TCP3 | NA | ||
Interconnection Type | |||||
Master unit | Cable type NPN / PNP | D2RF-TMN / TMP | D2GF-TMN / TMP | NA | |
M8 QD 4pin, NPN / PNP | D2RF-TMCN4 / TMCP4 | D2GF-TMCN4 / TMCP4 | NA | ||
Slave unit | Cable type NPN / PNP | D2RF-TSN / TSP | D2GF-TSN / TSP | NA | |
M8 QD 4pin, NPN / PNP | D2RF-TSCN4 / TSCP4 | D2GF-TSCN4 / TSCP4 | NA | ||
Light source | Red LED | Green LED | Red LED | ||
Response time | 60 micro sec (Fast mode ), 250 micro sec (standard), 2.0 ms (Long distance) | ||||
Auto control system | APC / ASC | ||||
LED Power control | 3 steps ; 100%, 50% and 25% | ||||
Timer functions | On delay/Off delay /One shot, 1-9,999msec (1msec increment) | ||||
Sensitivity adjustment | Teach-in + fine adjustment | ||||
Output indicator | Output (orange) : 1CH / 2CH common | Output (orange) | |||
Digital indicator | 7 segment LED, 4 digits in Red, 4 digits in Green | ||||
Teach-in mode | Full Power / One point / Two points / Full Automatic / Differential / Zone / Transparent | ||||
Control output | 2CH, NPN or PNP open collector, DC30V, 100mA Max | 1CH, NPN or PNP | |||
Parallel installation | Up to 16 sets | ||||
Crosstalk prevention | Up to 4 sets | ||||
Operating mode | Light on / Dark on selectable | ||||
Sensing mode | Long Distance Mode, Standard, Fast mode, | ||||
Display | Regular dislay plus ; bar, %, eco (off, run mode only) | ||||
External input | Teaching / Counter Reset | ||||
Supply voltage | DC 10-24V +/- 10% ripple | ||||
Power consumption | 45mA Max (24V) | ||||
Circuit protection | Reverse Polarity, Overcurrent, Short circuit | ||||
Warm-up time | 100m sec | ||||
Operating temp / humidity | ?25 to 55?, 35 to 85% RH | ||||
Storage temp / humidity | ?40 to 70?, 35 to 85% RH | ||||
Environmental illuminance | Sunlight 10,000 lux, High Frequency Lamp 3,000 lux | ||||
Protection category | IEC, IP50 (except Stand-alone IP66 types) | ||||
Comformity | EC, CE | ||||
Shock resistance | IEC 68, 50G | ||||
Weight | Cable type 21g, M8 connector type 23g | ||||
Factory default settings | Response time (Standard), Output (Light On), Timer (OFF), APC (OFF), |